Lurker News

Comments (366) 114 threads

Show all comments

Showing thread 2 of 114

sillysaurusx12 replies#
HN was down because the failover server also failed: https://twitter.com/HNStatus/status/1545409429113229312

Double disk failure is improbable but not impossible.
The most impressive thing is that there seems to be no dataloss, almost whatsoever. Whatever the backup system is, it seems rock solid.

hunterb1232 replies#
What was the test to determine the dataloss?
Cerium1 reply#
I came to the same conclusion by observing that there are posts and comments from only eight hours ago.
jbverschoor11 replies#
So that means dataloss.. Probably restored from backup.

Good news for people who were banned, or for posts that didn't get enough momentum :)
edit: Was restored from backup.. so def. dataloss

Continue this thread — 11 replies

sillysaurusx#
Informal. My last upvote was pretty close to when HN went down, so I expected my karma to go down, but it didn't.

Also I remember the "Why we're going with Rails" story on the front page from before it went down.

dboreham#
CP => !A
pastor_bob4 replies#
is dang pushing changes and such on his own?

sounds like it is run by one guy

sillysaurusx1 reply#
HN will be around a hundred years. I think it's more than just a forum. We've seen lots of people coordinate during disasters, for example. Dan and his team do a good job running it. (I'm not a part of it.)

EDIT: My response was based on some edits that are now removed.

rat998813 replies#
You are overstimating HN way too much.

Continue this thread — 13 replies

jacquesm1 reply#
What makes you think that? That's just a tweet from an unrelated account.
pastor_bob#
Nevermind, I thought the OP ran that twitter account
swyx1 reply#
theres two people fulltime on it but dang appears to be both DBA and SRE
openthc#
And Mod; hope he gets three cheques
dang#
I push changes on my own all the time, but the work of getting HN running again today was overwhelmingly done by my brilliant colleague mthurman.
davedunkin6 replies#
> Double disk failure is improbable but not impossible.

It's not even improbable if the disks are the same kind purchased at the same time.

spiffytech5 replies#
Yep: if you buy a pair disks together, there's a fair chance they'll both be from the same manufacturing batch, which correlates with disk defects.
clintonwoo10 replies#
This makes total sense but I've never heard of it. Is there any literature or writing about this phenomenon?

I guess proper redundancy is having different brands of equipment also in some cases.

Continue this thread — 10 replies

bragr2 replies#
Yeah just coming here to say this. Multiple disk failures are pretty probable. I've had batches of both disks and SSDs with sequential serial numbers, subjected to the same workloads, all fail within the same ~24 hour periods.

Continue this thread — 2 replies

GekkePrutser1 reply#
Eek - now I'm glad I wait a few months before buying each disk for my NAS.

Not doing it for this reason but rather financial ones :) But as I have a totally mixed bunch of sizes I have no RAID and a disk loss would be horrible.

Continue this thread — 1 reply

sofixa#
That's why serious SAN vendors take care to provide you a mix of disks (e.g. on a brand new NetApp you can see that disks are of 2-3 different types, and with quite different serial numbers).
dspillett#
This is why I try to mismatch manufacturers in RAID arrays. I'm told there is a small performance hit (things run towards the speed of the slowest, separately in terms of latency and throughput) but I doubt the difference is high and I like the reduction in potential failure-during-rebuild rates. Of course I have off-machine and off-site backups as well as RAID, but having to use them to restore a large array would be a greater inconvenience than just being able to restore the array (followed by checksum verifies over the whole lot for paranoia's sake).
kabdib2 replies#
I once had a small fleet of SSDs fail because they had some uptime counters that overflowed after 4.5 years, and that somehow persistently wrecked some internal data structures. It turned them into little, unrecoverable bricks.

It was not awesome seeing a bunch of servers go dark in just about the order we had originally powered them on. Not a fun day at all.

mikiem3 replies#
You are never going to guess how long the HN SSDs were in the servers... never ever... OK... I'll tell you: 4.5years. I am not even kidding.
kabdib6 replies#
Let me narrow my guess: They hit 4 years, 206 days and 16 hours . . . or 40,000 hours.

And that they were sold by HP or Dell, and manufactured by SanDisk.
Do I win a prize?
(None of us win prizes on this one).

mikiem#
These were made by SanDisk (SanDisk Optimus Lightning II) and the number of hours is between 39,984 and 40,032... I can't be precise because they are dead and I am going off of when the hardware configurations were entered in to our database (could have been before they were powered on) or when we handed them over to HN, and when the disks failed.

Unbelievable. Thank you for sharing your experience!

dang2 replies#
Wow. It's possible that you have nailed this.

Edit: here's why I like this theory. I don't believe that the two disks had similar levels of wear, because the primary server would get more writes than the standby, and we switched between the two so rarely. The idea that they would have failed within hours of each other because of wear doesn't seem plausible.
But the two servers were set up at the same time, and it's possible that the two SSDs had been manufactured around the same time (same make and model). The idea that they hit the 40,000 hour mark within a few hours of each other seems entirely plausible.
Mike of M5 (mikiem in this thread) told us today that it "smelled like a timing issue" to him, and that is squarely in this territory.

tempestn1 reply#
This kind of thing is why I love Hacker News. Someone runs into a strange technical situation, and someone else happens to share their own obscure, related anecdote, which just happens to precisely solve the mystery. Really cool to see it benefit HN itself this time.
dang3 replies#
It's also an example of the dharma of /newest – the rising and falling away of stories that get no attention:

HPE releases urgent fix to stop enterprise SSDs conking out at 40K hours - https://news.ycombinator.com/item?id=22706968 - March 2020 (0 comments)
HPE SSD flaw will brick hardware after 40k hours - https://news.ycombinator.com/item?id=22697758 - March 2020 (0 comments)
Some HP Enterprise SSD will brick after 40000 hours without update - https://news.ycombinator.com/item?id=22697001 - March 2020 (1 comment)
HPE Warns of New Firmware Flaw That Bricks SSDs After 40k Hours of Use - https://news.ycombinator.com/item?id=22692611 - March 2020 (0 comments)
HPE Warns of New Bug That Kills SSD Drives After 40k Hours - https://news.ycombinator.com/item?id=22680420 - March 2020 (0 comments)
(there's also https://news.ycombinator.com/item?id=32035934, but that was submitted today)

winternett1 reply#
Interesting how something that is so specifically and unexpectedly devastating, yet known for such a long time without any serious public awareness from companies involved, is referred to as a "bug".

It makes you lose data and need to purchase new hardware, where I come from, that's usually referred to as "planned" or "convenient" obsolescence.

mulmen1 reply#
The difference between planned and convenient seems to be intent. And in this context that difference very much matters. I wouldn’t conflate the two.
winternett1 reply#
Depends on who exactly we are talking about as having the intent...

Both planned and convenient obsolescence are beneficial to device manufacturers. Without proper accountability for that, it only becomes a normal practice.

Continue this thread — 1 more reply

Continue this thread — 2 more replies

Continue this thread — 1 more reply

Continue this thread — 4 more replies

chinathrow2 replies#
How many other customers will/have hit this?

Continue this thread — 2 replies

Continue this thread — 1 more reply

rbanffy#
I had a similar issue, but it was a single RAID-5 array and wear of some other manufacture defect. They were the same brand, model, and batch. When the first failed and the array got in recovery mode I ordered 3 replacements and upped the backup frequency. It was good that I did that because the two remaining drives died shortly after.

The lesson I learned is that the three replacements went to different arrays and we never again let drives from the same batch be part of the same array.

0xbadcafebee2 replies#
Even if they're not the same, they're written at the same time and rate, meaning they have the same wear over time, subject to the same power/heat issues, etc.

Continue this thread — 2 replies

Continue this thread — 3 more replies

Continue this thread — 8 more replies