Tell HN: The 10-bit timers are about to overflow on September 17th
400 pointsLoss of historical data and event logs, logging and security problems, loss of process visualization - these are some of the surprises that can happen when, having received the wrong date, other devices also decide to "time travel."
What to do?
If your network is running one of the aforementioned devices, it's best to disconnect it in advance. Unfortunately, most of them are no longer supported by the manufacturer and no patches are expected. So it looks like they will become quite useless after September 17.
This leaves very little time, therefore, to replace them with new solutions. If you are not sure whether the problem also affects your device, you can unplug it on September seventeenth, and if it shows the correct date the next day, plug it in again. Of course, such a maneuver is possible only in those networks that can operate without time synchronization according to GPS for several/some hours.
Comments (75) 15 threads
Show all comments
Showing thread 10 of 15
(1) Technically the modernized L2C/L1C/L5 signals use a 13-bit week number, but because the deployment of these signals was massively delayed receivers using them are basically non-existent today. (I also have no idea if the current receivers supporting them successfully use the 13-bit week number, given that they're not guaranteed to be able to receive the modernized signals as they're still less available than L1)
I'm not aware of any devices that implement a rollover counter but there may be some, though a rollover counter needs to figure out how to deal with corrupted or spoofed signals and will have issues like spares off the shelf not working like the device they're replacing.