- lifts wont operate.
- cant disarm the building alarms. (have been blaring nonstop...)
- cranes are all locked in standby/return/err.
- laser aligners are all offline.
- lathe hardware runs but controllers are all down.
- cant email suppliers.
- phones are all down.
- HVAC is also down for some reason (its getting hot in here.)
the police drove by and told us to close up for the day since we dont have 911 either.
alarms for the building are all offline/error so we chained things as best we could (might drive by a few times today.)
we dont know how many orders we have, we dont even know whos on schedule or if we will get paid.
Continue this thread — 1 reply
Continue this thread — 16 replies
Continue this thread — 1 reply
The cranes and lifts though... I've never heard of them being networked or controlled by a computer. Usually it's a couple buttons connected to the motors and that's it. But maybe they have some monitoring systems in them?
Continue this thread — 1 reply
These systems are intended to allow local control of a factory, or cloud based global control of manufacturing.
They can connect to individual PLC(Programmable Logic Controller) which handles the actual equipment.
They connect to a LAN network, or to the internet. So they naturally need some form of security.
They could use Windows Server, Redhat Linux, etc. but they need some form of security. Which is how controller would be affected.
Usually you can just set them to manual though...
The need a new copy of Windows because running an old copy on a network is a worse idea.
Continue this thread — 12 replies
Now we are reaping what we sowed.
Are they somehow controlled remotely? or do they need to ping a central server to be able to operate?
I can see how alarms, email and phones are affected but the heavy machinery?
(Clearly not familiar with any of these things so I am genuinely curious)
Once such a system is deployed why would it ever need to be updated?
Have we learned nothing from how the uranium enrichment machines were hacked in Iran? Or how attackers routinely move laterally across the network?
Everything is connected these days. For really good reasons.
Also the facility was air-gapped, so it wasn't connected to ANY outside network. They had to use other means to get Stux on those computers and then used something like 7 zero days to move from windows into Siemens computers to inflict damage.
Stux got out potentially because someone brought their laptop to work, the malware got into said laptop and moved outside the airgap from a different network.
The lesson here is that even in an air-gapped system the infrastructure should be as proprietary as is possible. If, by design, domestic Windows PCs or USB thumb drives could not interface with any part of the air-gapped system because (a) both hardwares were incompatible at say OSI levels 1, 2 & 3; and (b) software was in every aspect incompatible with respect to their APIs then it wouldn't really matter if by some surreptitious means these commonly-used products entered the plant. Essentially, it would be almost impossible† to get the Trojan onto the plant's hardware.
That said, that requires a lot of extra work. By excluding subsystems and components that are readily available in the external/commercial world means a considerable amount of extra design overhead which would both slow down a project's completion and substantially increase its cost.
What I'm saying is obvious, and no doubt noted by those who've similar intentions to the Iranians. I'd also suggest that the use of individual controllers etc. such as the Siemens ones used by Iran either wouldn't be used or they'd need to be modified from standard both in hardware and with the firmware (hardware mods would further bootstrap protection if an infiltrator knew the firmware had been altered and found a means of restoring the default factory version).
Unfortunately, what Stuxnet has done is to provide an excellent blueprint of how to make enrichment (or any other such) plants (chemical, biological, etc.) essentially impenetrable.
† Of course, that doesn't stop or preclude an insider/spy bypassing such protections. Building in tamper resistance and detection to counter this threat would also add another layer of cost and increase the time needed to get the plant up and running. That of itself could act as a deterrent, but I'd add that in war that doesn't account for much, take Bletchley and Manhattan where money was no object.
Continue this thread — 2 replies
Updates are partially necessary to ensure you don't end up completely unsupported in the future.
It's been a long time, but I worked IT for an auto supplier. Literally nothing was worse than some old computer crapping out with an old version of Windows and a proprietary driver. Mind you, these weren't mission critical systems, but they did disrupt people's workflows while we were fixing the systems. Think, things like digital measurements or barcode scanners. Everything can be easily done by hand but it's a massive pain.
Most of these systems end up migrated to a local data center than deployed via a thin client. Far easier to maintain and fix than some box that's been sitting in the corner of a shop collecting dust for 15 years.
Continue this thread — 20 replies
Yeah, can’t do it now: it’s all electronic.
Continue this thread — 1 reply
Because it can be remotely updated by attackers.
and if there's some sensor network in the building that should be completely separate from the actual machine controls.
Continue this thread — 7 replies
I would imagine they used specialized controller cards or something like that.
Continue this thread — 3 replies
I used to build sorting machines that use variants of the typical “industrial” tech stack, and the actual controllers are rarely (but not never!) Windows. But it’s common for the HMI to be a Windows box connected into the rest of the network, as well as any server.
Continue this thread — 4 more replies